Lincad Ltd

Design, Supply and Installation of 50 kWp photovoltaic system and bespoke display unit for entrance foyer.

Services included;

Structural assessment of roof

DNO application

3D modelling of photovoltaic installation using PV Sol 3D

Scaffold Access

FIT application assistance

DNO notification

188 Bisol 265w modules mounted on VanderValk trapezoidal roof mounting system feeding two number Solis three phase inverters.

Peter Slade, Project Manager at Lincad, said: “As a power management company, it makes total sense for Lincad to take advantage of readily available solar energy to reduce costs and improve the efficiency of our operations. And, significantly, it allows us to reduce our carbon footprint, further illustrating that Lincad takes its environmental responsibilities very seriously.”

< GO BACK
  • Location: Guildford
  • System Size: 50 kWp
  • Panel Model: Bisol 265w
  • Inverter Model: Solis
  • Annual Output: 42,194 kWh
  • Annual CO2 Savings: 22,320 kg
  • Annual Energy Savings Units: 31646kW
  • Estimated Annual Benefit (£): FIT & EXPORT TARIFF'S £2,423.00
  • Estimated Annual Savings (£): £4114.00
  • Estimated Annual Total Savings (£): £6,537.00
  • Estimated Benefit Over Lifetime (£): £141,151.00